ABC Fire Extinguisher 6 kg – Price in India & Complete Fire Fighting Supplies

From ISI-marked 6 kg ABC extinguishers to turnkey fire hydrant installation, hose reels, fire bucket stands, fire blankets and aluminised proximity suits — Sure Safety designs, supplies and commissions fire protection across India.

ABC Fire Extinguisher 6 kg – Price, Ratings and Placement

The 6 kg ABC dry chemical powder extinguisher is the workhorse of Indian fire safety. Filled with mono-ammonium phosphate (MAP) powder, it tackles Class A (wood, paper, textiles), Class B (flammable liquids) and Class C (flammable gases) fires, and is safe on live electrical equipment up to the voltage stated on the label. Extinguishers should conform to IS 15683 and carry the ISI mark; selection and placement follow IS 2190.

FeatureStored pressure typeCartridge type
OperationPressurised with N2, gauge shows pressureCO2 cartridge pierced on use
MaintenanceEasy pressure check via gaugeCartridge weighed periodically
Typical useOffices, retail, factoriesHeavy industry, harsh environments
Discharge timeApprox. 13–15 seconds, range about 4–6 metres

The ABC fire extinguisher 6 kg price in India depends on powder concentration (MAP 40% vs. MAP 90%), stored pressure vs. cartridge design, brand, body material and accessories such as wall brackets and stands. MAP 90 powder delivers higher fire ratings and is preferred for industrial sites. We supply ISI-marked extinguishers with installation, signage, refilling and annual maintenance — get a quote for your floor plan and we will recommend quantities and locations.

For electrical rooms, pair with CO2 extinguishers; for kitchens, use Class K wet chemical units along with a fire blanket. Browse our full fire protection products.

Fire Hydrant System Installation in India

For factories, warehouses, high-rise buildings and process plants, portable extinguishers alone are not enough. A fire hydrant system provides a reliable water supply at high pressure for manual firefighting across the premises. Sure Safety provides end-to-end fire hydrant system installation in India — from hydraulic design and approvals to supply, installation, testing and commissioning.

  • Design per codes: National Building Code 2016 Part 4, IS 13039, IS 3844 and applicable TAC/insurance guidelines.
  • Components: fire water tank, main electric pump, diesel pump, jockey pump, ring main, landing valves, hose boxes, hose reels and fire brigade inlets.
  • Testing: hydrostatic testing of piping, pump performance tests and flow tests at remote hydrants.
  • AMC: periodic inspection, pump runs, valve servicing and hose testing.

Our project credentials include hydrant systems, high-velocity water spray systems for transformers and fire water networks for chemical and manufacturing clients. Learn more on our fire protection services page and see sector work in petrochemical and energy fire protection. We also conduct fire safety audits.

Fire Hose Reel Drum 30 Meter – Price and Specifications

A first-aid hose reel lets trained occupants attack a fire early with a continuous water supply, before it grows beyond extinguisher capacity. The standard fire hose reel drum with 30 meter thermoplastic or rubber hose conforms to IS 884 and connects directly to the hydrant ring main or a dedicated riser.

ParameterTypical specification
Hose length30 metres (also 20/45 m)
Hose diameter19 mm or 25 mm
DrumSwinging or fixed, MS powder-coated, red
NozzleShut-off nozzle, brass or gunmetal
ValveBall valve isolation
MountingWall-mounted or inside hose cabinet

The fire hose reel drum 30 meter price varies with hose diameter, hose material (rubber vs. thermoplastic), drum type (swinging vs. fixed), nozzle metal and whether a cabinet is included. Contact us for a configuration-wise quotation.

Fire Bucket Stand with 4 Buckets – Price and Use

Simple but effective, a fire bucket stand with 4 buckets filled with dry sand or water is required in many factories, fuel stations, transformer yards, warehouses and construction sites. Buckets conforming to IS 2546 are made of galvanised or MS sheet with a round bottom (to discourage misuse), painted signal red with “FIRE” marked in white.

  • Standard set: 4 buckets of roughly 9 litres capacity on an MS angle stand with a canopy/roof.
  • Sand buckets for oil and electrical fires; water buckets for Class A materials.
  • Powder-coated stands resist corrosion in outdoor yards.

The fire bucket stand with 4 buckets price depends on sheet gauge, stand construction (with or without canopy) and finish. Bulk orders for multiple locations attract better rates.

Fire Blanket for Kitchen and Industrial Use

A fire blanket smothers small fires by cutting off oxygen, and can be wrapped around a person whose clothing has caught fire. A fire blanket for kitchen and industrial use is made of woven glass fibre or high-temperature silica fabric, packed in a quick-release wall pouch. Kitchen blankets typically meet EN 1869, while heavy industrial blankets in larger sizes are used for welding, laboratories and furnaces.

1.2 m × 1.2 m

Home, office pantries and commercial kitchens.

1.2 m × 1.8 m

Laboratories, canteens and process areas.

1.8 m × 1.8 m and larger

Welding bays, foundries and wrapping a person.

Aluminised Fire Proximity Suit – Price in India

When firefighters or furnace operators must approach intense radiant heat — aircraft fires, tank fires, blast furnaces, tapping operations or kiln repairs — ordinary turnout gear is not enough. An aluminised fire proximity suit reflects up to around 90–95% of radiant heat. Suits are tested to EN ISO 11612 and EN 1486 (for reflective firefighting clothing).

  • Outer layer: aluminised aramid or aluminised glass fabric.
  • Thermal liner and moisture barrier for insulation.
  • Components: coat, trousers, hood with gold-coated visor, gloves and boot covers.
  • Options: SCBA-compatible hood/back hump, one-piece or two-piece design.

The aluminised fire proximity suit price in India depends on base fabric (aramid vs. glass), the number of layers, visor quality, and whether gloves and boot covers are included. Pair with our 500°C heat-resistant gloves and SCBA sets. Specialised vehicles and leak control systems are on our speciality page.

Need help deciding the mix of equipment for a new facility? Our engineers prepare a fire equipment layout covering extinguisher types and quantities, hose reel coverage, hydrant spacing, bucket stand locations and signage, so you can budget accurately and meet inspection requirements on the first visit.

Frequently Asked Questions

How often should a 6 kg ABC extinguisher be refilled?

Extinguishers must be inspected regularly and maintained per IS 2190. Refill immediately after any use, and follow the manufacturer's and IS 2190's schedule for refilling, pressure testing and replacement.

Can ABC extinguishers be used on electrical fires?

ABC powder is non-conductive and is commonly used on electrical fires up to the voltage on the label, but CO2 is preferred for sensitive electronics as it leaves no residue.

Do you handle fire NOC documentation?

We support design documentation, drawings and test records needed for approvals. Our consulting team also conducts fire audits.

Do you provide fire fighting training?

Yes. Our training team runs extinguisher handling, hydrant operation and emergency response drills. See also our fire safety and NEBOSH guide.

Plan Your Fire Protection with Sure Safety

Share your quantity, application and delivery location — our team responds with a technical recommendation and a competitive quotation.

Scroll to Top

Fire Audit

A systematic examination of a building or facility to assess its fire safety measures and ensure compliance with regulations. Its primary purpose is to identify potential fire hazards, evaluate the effectiveness of existing safety systems like alarms and sprinklers, and check for things like clear fire exits and proper employee training. The audit provides a comprehensive report with recommendations for improvements to protect occupants and property. Key aspects:

  • Hazard identification
  • Equipment evaluation
  • Structural and physical checks
  • Emergency preparedness
  • Compliance checks
  • Respiratory Fit Testing : Respiratory Fit Testing services are available at your location or ours. SIIPL’s offers both Qualitative and Quantitative Fit Testing methods. Proper mask fit is crucial in minimizing risk to contaminate on the job. All personnel who have the potential to be exposed to contaminate are required to have fit testing performed on an annual basis in compliance with OSHA and MSHA regulations.
    Qualitative Fit Testing is performed when using half mask respirators and relies on the senses of taste and smell or reaction to an irritant to determine leakage.
    Quantitative Fit Testing can be used for any type of respirator and is performed using a machine to determine the actual leakage into the face piece.
    All persons who are scheduled to have fit testing performed must be medically evaluated prior to the test date to ensure the attendee is medically able to wear the respirator. In addition, all attendees must be clean shaven in order undergo testing.

Hazop

A structured and systematic method for identifying potential hazards and operability problems in complex systems, such as a chemical plant or oil refinery. It is a form of Process Hazard Analysis that helps organizations proactively identify risks before an incident occurs by examining how a process can deviate from its design intent.

Safety Audits (Is14489)

This is a systematic examination of an organization's safety management system, policies, and procedures to identify potential hazards, evaluate safety practices, and ensure compliance with regulations. The primary goals are to prevent accidents, improve the work environment, and reduce costs associated with injuries, while fostering a stronger safety culture.
Includes:

  • Hazard identification
  • Compliance verification
  • System evaluation
  • Recommendation for improvement
  • Employee involvement

Ergonomics Assessment

A professional evaluation of a worker's workstation and job tasks to identify risks for injury and discomfort with a goal to make adjustments to the work setup, equipment, or tasks to reduce physical hazards like awkward postures, repetitive motions, and forceful movements, thereby improving comfort, safety, productivity, and well-being

  • Observation: A professional observes how an individual works, sits, and interacts with their environment.
  • Evaluation : The assessor evaluates factors like workstation setup (desk, chair, monitor height), posture, repetitive movements, and force used in the job.
  • Information Gathering : Questions may be asked about daily tasks, previous injuries, and individual characteristics to understand the current situation.
  • Risk identification : The assessment identifies potential risk factors that could lead to musculoskeletal disorders (MSDs), such as carpal tunnel syndrome or back pain.
  • Recommendations : Based on the findings, recommendations are provided for adjustments or new equipment to improve the work environment.

Noise Mapping & Assessment

SSIL provides Noise Surveys to determine the extent of long- or short-term noise levels in your facility. Identification of areas with high noise levels helps to protect your employees hearing and helps you to determine proper hearing protection requirements and define the areas where different levels of hearing protection must be worn.
Noise Surveys include the use of the latest equipment and a report outlining the findings from the survey including site mapping. OSHA and MSHA mandate that your employees wear the proper hearing protection for the environment they work in. Have your noise levels checked today to ensure you’re in compliance.
It helps in designing engineering controls to meet the noise reduction requirement of high noise areas of the plant.

Ppe Audit

  • Assessment of current PPE selection status
  • PPE selection guidelines
  • PPE program implementation
  • PPE qualitative & quantitative fit testing program

The audit identifies any gaps in the PPE program, which helps the company take corrective actions to
improve worker safety and compliance.

Qualitative Exposure Assessment

  • Walk through Survey (Qualitative study) to identify Location & Name of Hazards for further Quantitative study to improve work environment.

Indoor Air Quality Program

Indoor Air Quality (IAQ) may be the edge between productive & unproductive manpower for any Organization. Emphasis on IAQ is increasing in a highly competitive and challenging business environment. We offer IAQ services for the physical, chemical and biological characteristics of air inside a building or any commercial facility. Poor IAQ may cause workers, occupants and even the
Visiting public to experience a range of non-specific symptoms that affect their comfort or health. These symptoms collectively known as sick building syndrome which includes headache, fatigue, nausea, eye or nose or throat irritation, shortness of breath etc.

  • Monitoring & Analysis for various Physical, chemical, Aerosols & Microbiological Pollutants/Hazards like Temperature, RH, CO2, CO, O2, TVOC, PM10, PM2.5, TBC, TFC, etc. as per requirement, for controlled closed Air Conditioned office facilities like MNC´s, Software industries, Hotels, Call Centers, Hospitals, etc.
  • Survey of the Building including AHU & Air conditioning systems and surrounding area of the building to identify source/ cause of problem, if any

Heat Stress Assessment

  • Measurement of heat to understand the heat exposure to people and the area. This also helps design ventilation to improve the comfort of people working at the area.

API & Surrogate Assessment

  • Measure the actual exposure of API while working in pharmaceutical units or critical drug manufacturing.

Industrial Hygiene Study

SSIL is an AIHA, NABL accredited company that is registered and approved with all applicable legal and regulatory bodies, major industries. With more than 15 years of technical expertise and professional know-how, SSIL targets all level of industry where quality, safety and compliance are critical elements that affect the performance of any Organization.
Industrial (Occupational) Hygiene is science dedicated to the anticipation, recognition, evaluation, communication and control of environmental stressors in, or arising from, the workplace that may result in injury, illness, impairment, or affect the wellbeing of workers and members of the community.
These stressors are divided into different categories e.g. Biological, Chemical, Physical, Ergonomic and Psychosocial. Industrial Hygiene services offered by us are :

  • Walk through Survey (Qualitative study) to identify Location & Name of Hazards for further Quantitative study to improve work environment.
  • Monitoring & Analysis for various Pharmaceutical, Mining, Automobile, Paint, Petroleum, Cement, IT, Manufacturing and Construction Industries, etc. Industries for the following Hazards.
    • DUST (Personal/ Workplace)
    • OEL monitoring
    • Solvent Vapours/ Fumes (Personal/ Workplace)
    • Welding Fumes
    • Noise (Area, Mapping, Dosimetry)
    • Heat Stress (Personal/ Workplace)
    • Illumination
    • Whole Body/ Hand Arm Vibration
    • Breathing Air/ Compressed Air/ Nitrogen Testing
    • Indoor Air Quality (IAQ) Monitoring
    • Ergonomics Assessment
    • Vibration Monitoring
    • Legionella Survey & Monitoring
    • Heavy Metal Exposure Assessments
    • State-based Form 37 and 26-A monthly monitoring
    • Isolator Validation Program
    • Crystalline Silica Quantification Program
  • Consultancy for the Improvement in working condition for various Hazards.