Suresafety India Limited

Electrical Hand Protection

Electrical Insulating Gloves 11kV & 33kV – Price, Classes & Specifications

IS 4770 / IEC 60903 certified rubber insulating gloves from Class 00 to Class 4 for LV, 11kV, 22kV and 33kV work. Batch-tested, supplied with leather protectors and test certificates by Sure Safety.

Electrical insulating gloves are the primary personal barrier between a lineman's hands and a live conductor. Unlike general rubber gloves, they are made from high-dielectric natural or synthetic rubber, manufactured without seams or pinholes, and proof-tested at voltages far above their working rating. Sure Safety supplies electrical insulating gloves for 11kV and 33kV systems to power utilities, substations, transformer manufacturers, EPC contractors and industrial maintenance teams across India.

Electrical Insulating Glove Classes and Voltage Ratings

Gloves are classified under IEC 60903 and IS 4770 by maximum working voltage. Each glove carries a coloured class label so the correct rating can be verified at a glance before work begins.

ClassLabel colourMax working voltage (AC)Proof test voltage (AC)Typical system
00Beige500 V2.5 kVControl panels
0Red1 kV5 kVLV distribution, MCC
1White7.5 kV10 kV3.3kV / 6.6kV
2Yellow17 kV20 kV11kV
3Green26.5 kV30 kV22kV
4Orange36 kV40 kV33kV

11kV Electrical Insulating Gloves (Class 2)

For 11kV feeders, ring main units, distribution transformers and HT switchgear, Class 2 gloves rated for 17kV maximum working voltage are the standard specification. They provide a safety margin above the nominal 11kV system voltage while keeping enough flexibility for terminating, testing and switching tasks.

  • Length options: 360 mm and 410 mm to protect the wrist and forearm.
  • Thickness approximately 2.3–2.5 mm, balancing protection and dexterity.
  • Sizes 8 to 11 to ensure a correct fit — loose gloves reduce grip and control.
  • Variants with ozone (Category Z) and oil (Category H) resistance for outdoor and transformer work.

33kV Electrical Insulating Gloves (Class 4)

For 33kV lines, substation bays and grid maintenance, Class 4 gloves rated for 36kV are required. They are thicker, longer and stiffer than lower classes, and are always used with leather protector gloves and, in live-line work, with insulated tools and sleeves.

  • Length typically 410 mm or longer for full forearm coverage.
  • Thickness up to approximately 3.6 mm.
  • Used with insulating sleeves, hot sticks and insulated platforms during live-line maintenance.
Important: A glove's class must equal or exceed the maximum voltage of the system being worked on. Never use an 11kV (Class 2) glove on a 33kV system.

Electrical Insulating Gloves 11kV 33kV Price – What Affects It

The electrical insulating gloves 11kv 33kv price depends mainly on the class, because higher classes use more rubber and undergo more demanding testing. A 33kV Class 4 pair costs considerably more than an 11kV Class 2 pair. Other factors include:

FactorEffect on price
Voltage class (Class 2 vs Class 4)Biggest driver — higher class, higher price
Length (360 mm vs 410 mm+)Longer gloves cost more
Special categories (ozone, oil, low-temperature)Adds to cost
Leather over-protectorsSold separately or as a kit
Brand and certificationImported brands vs Indian certified gloves
Quantity / rate contractBulk utility orders attract better pricing

Share the voltage class, size breakup and quantity, and our team will send a quotation with test certificates. Utilities and EPC contractors can request annual rate contracts.

Safe Use, Testing and Storage

  1. Air test before every use: roll the cuff to trap air and check for leaks, cuts or pinholes.
  2. Always wear leather protectors over rubber gloves to prevent punctures and abrasion.
  3. Periodic dielectric retest: IEC 60903 recommends retesting gloves in use, commonly every six months.
  4. Store correctly: flat, in a glove bag, away from sunlight, heat, ozone (motors, transformers) and sharp objects. Never fold.
  5. Remove jewellery and check the class label before each job.

Combine gloves with our electrical safety equipment — insulating mats, discharge rods and voltage detectors — and 18kV electrical insulated safety shoes. See also our power plant safety solutions.

Frequently Asked Questions

Which glove class is required for 11kV work?

Class 2 gloves, rated for 17kV maximum working voltage, are generally specified for 11kV systems. Always follow your utility or site electrical safety rules.

Which glove class is required for 33kV work?

Class 4 gloves, rated for 36kV maximum working voltage, are used for 33kV systems along with leather protectors and other insulating equipment.

Why do 33kV gloves cost more than 11kV gloves?

Class 4 gloves are thicker, longer and tested at higher proof voltages, which requires more material and stricter quality control.

Do you provide test certificates?

Yes, gloves are supplied with batch test certificates as per IS 4770 / IEC 60903.

Get Certified 11kV & 33kV Insulating Gloves

Share your quantity, application and delivery location — our team responds with a technical recommendation and a competitive quotation.

Scroll to Top

Fire Audit

A systematic examination of a building or facility to assess its fire safety measures and ensure compliance with regulations. Its primary purpose is to identify potential fire hazards, evaluate the effectiveness of existing safety systems like alarms and sprinklers, and check for things like clear fire exits and proper employee training. The audit provides a comprehensive report with recommendations for improvements to protect occupants and property. Key aspects:

  • Hazard identification
  • Equipment evaluation
  • Structural and physical checks
  • Emergency preparedness
  • Compliance checks
  • Respiratory Fit Testing : Respiratory Fit Testing services are available at your location or ours. SIIPL’s offers both Qualitative and Quantitative Fit Testing methods. Proper mask fit is crucial in minimizing risk to contaminate on the job. All personnel who have the potential to be exposed to contaminate are required to have fit testing performed on an annual basis in compliance with OSHA and MSHA regulations.
    Qualitative Fit Testing is performed when using half mask respirators and relies on the senses of taste and smell or reaction to an irritant to determine leakage.
    Quantitative Fit Testing can be used for any type of respirator and is performed using a machine to determine the actual leakage into the face piece.
    All persons who are scheduled to have fit testing performed must be medically evaluated prior to the test date to ensure the attendee is medically able to wear the respirator. In addition, all attendees must be clean shaven in order undergo testing.

Hazop

A structured and systematic method for identifying potential hazards and operability problems in complex systems, such as a chemical plant or oil refinery. It is a form of Process Hazard Analysis that helps organizations proactively identify risks before an incident occurs by examining how a process can deviate from its design intent.

Safety Audits (Is14489)

This is a systematic examination of an organization's safety management system, policies, and procedures to identify potential hazards, evaluate safety practices, and ensure compliance with regulations. The primary goals are to prevent accidents, improve the work environment, and reduce costs associated with injuries, while fostering a stronger safety culture.
Includes:

  • Hazard identification
  • Compliance verification
  • System evaluation
  • Recommendation for improvement
  • Employee involvement

Ergonomics Assessment

A professional evaluation of a worker's workstation and job tasks to identify risks for injury and discomfort with a goal to make adjustments to the work setup, equipment, or tasks to reduce physical hazards like awkward postures, repetitive motions, and forceful movements, thereby improving comfort, safety, productivity, and well-being

  • Observation: A professional observes how an individual works, sits, and interacts with their environment.
  • Evaluation : The assessor evaluates factors like workstation setup (desk, chair, monitor height), posture, repetitive movements, and force used in the job.
  • Information Gathering : Questions may be asked about daily tasks, previous injuries, and individual characteristics to understand the current situation.
  • Risk identification : The assessment identifies potential risk factors that could lead to musculoskeletal disorders (MSDs), such as carpal tunnel syndrome or back pain.
  • Recommendations : Based on the findings, recommendations are provided for adjustments or new equipment to improve the work environment.

Noise Mapping & Assessment

SSIL provides Noise Surveys to determine the extent of long- or short-term noise levels in your facility. Identification of areas with high noise levels helps to protect your employees hearing and helps you to determine proper hearing protection requirements and define the areas where different levels of hearing protection must be worn.
Noise Surveys include the use of the latest equipment and a report outlining the findings from the survey including site mapping. OSHA and MSHA mandate that your employees wear the proper hearing protection for the environment they work in. Have your noise levels checked today to ensure you’re in compliance.
It helps in designing engineering controls to meet the noise reduction requirement of high noise areas of the plant.

Ppe Audit

  • Assessment of current PPE selection status
  • PPE selection guidelines
  • PPE program implementation
  • PPE qualitative & quantitative fit testing program

The audit identifies any gaps in the PPE program, which helps the company take corrective actions to
improve worker safety and compliance.

Qualitative Exposure Assessment

  • Walk through Survey (Qualitative study) to identify Location & Name of Hazards for further Quantitative study to improve work environment.

Indoor Air Quality Program

Indoor Air Quality (IAQ) may be the edge between productive & unproductive manpower for any Organization. Emphasis on IAQ is increasing in a highly competitive and challenging business environment. We offer IAQ services for the physical, chemical and biological characteristics of air inside a building or any commercial facility. Poor IAQ may cause workers, occupants and even the
Visiting public to experience a range of non-specific symptoms that affect their comfort or health. These symptoms collectively known as sick building syndrome which includes headache, fatigue, nausea, eye or nose or throat irritation, shortness of breath etc.

  • Monitoring & Analysis for various Physical, chemical, Aerosols & Microbiological Pollutants/Hazards like Temperature, RH, CO2, CO, O2, TVOC, PM10, PM2.5, TBC, TFC, etc. as per requirement, for controlled closed Air Conditioned office facilities like MNC´s, Software industries, Hotels, Call Centers, Hospitals, etc.
  • Survey of the Building including AHU & Air conditioning systems and surrounding area of the building to identify source/ cause of problem, if any

Heat Stress Assessment

  • Measurement of heat to understand the heat exposure to people and the area. This also helps design ventilation to improve the comfort of people working at the area.

API & Surrogate Assessment

  • Measure the actual exposure of API while working in pharmaceutical units or critical drug manufacturing.

Industrial Hygiene Study

SSIL is an AIHA, NABL accredited company that is registered and approved with all applicable legal and regulatory bodies, major industries. With more than 15 years of technical expertise and professional know-how, SSIL targets all level of industry where quality, safety and compliance are critical elements that affect the performance of any Organization.
Industrial (Occupational) Hygiene is science dedicated to the anticipation, recognition, evaluation, communication and control of environmental stressors in, or arising from, the workplace that may result in injury, illness, impairment, or affect the wellbeing of workers and members of the community.
These stressors are divided into different categories e.g. Biological, Chemical, Physical, Ergonomic and Psychosocial. Industrial Hygiene services offered by us are :

  • Walk through Survey (Qualitative study) to identify Location & Name of Hazards for further Quantitative study to improve work environment.
  • Monitoring & Analysis for various Pharmaceutical, Mining, Automobile, Paint, Petroleum, Cement, IT, Manufacturing and Construction Industries, etc. Industries for the following Hazards.
    • DUST (Personal/ Workplace)
    • OEL monitoring
    • Solvent Vapours/ Fumes (Personal/ Workplace)
    • Welding Fumes
    • Noise (Area, Mapping, Dosimetry)
    • Heat Stress (Personal/ Workplace)
    • Illumination
    • Whole Body/ Hand Arm Vibration
    • Breathing Air/ Compressed Air/ Nitrogen Testing
    • Indoor Air Quality (IAQ) Monitoring
    • Ergonomics Assessment
    • Vibration Monitoring
    • Legionella Survey & Monitoring
    • Heavy Metal Exposure Assessments
    • State-based Form 37 and 26-A monthly monitoring
    • Isolator Validation Program
    • Crystalline Silica Quantification Program
  • Consultancy for the Improvement in working condition for various Hazards.